WALK-IN COOLING (COLD ROOM) CHAMBERS

These are medium to large-sized chambers that are custom-built to ensure that they not only fit optimally in your lab's stability area but also address your large-scale stability testing requirements.

Walk-In Chambers have now become a de-facto requirement for companies planning multiple ANDA filings & planning to launching various products simultaneously.

NEWTRONIC Walk-Ins ensure a smooth air-flow pattern to improve the temperature & humidity distribution across the chamber. This has also led to huge load reduction on the heating, cooling & humidifier systems. This & many other innovations in the construction & design aspects have ensured dramatic reduction in power consumption of our Walk-Ins.

NEWTRONIC has also been regularly exporting the Walk-In Chambers to all the major markets of the world. We ensure our products meet all kinds of country-specific requirements such as voltage specifications, regulatory needs, container shipping, etc



Features

  • High-speed data transfer
  • Significantly faster than serial(RS-485) communication
  • Global standard for communication protocol
  • No need for a separate PC interface
  • Data Operations from any PC over the LAN
  • Complete Operations driven through PLC
  • No Data Loss: Data Storage of upto 1000 readings on the PLC itself
  • At an interval of 30 mins, data upto 20 days is stored on the PLC itself
  • Facility to send emails directly from the PLC
  • All operations through a single 4" Color touch screen display
  • PLC IP Address setting
  • Component Working Hours
  • Standby system change over
  • Password protection for set values and calibration mode
  • Completely ready-to-use systems
  • Automatic switch-over upon failure of primary systems to achieve conditions
  • Switch-over also upon detection of HP/LP & Internal fault
  • Scheduled & manual change-overs
  • Recording of all change-overs in the software
  • Password based access control
  • Restricts access to unauthorized persons
  • Mobile alert system
  • Time of alarm transmission
  • Name of equipment
  • Transmitted message(Equipment name, alarm time,type of alarm & limits)
  • When an alarm is triggered, an e-mail is sent to the registered PC or mobile address
  • *connection to a mail server is required to use e-mail alert.
  • Temperature Overshoot/Undershoot
  • Humidity Overshoot
  • Low water-level
  • Delay Timer to safeguard the Compressor
  • MCB to cut-off over-current supply
  • Standby Controlling Sensor upon failure of Primary
  • In Walk-in chambers door can be open from inside
  • Emergency Bell switch inside the Chamber
  • 21 CFR Part 11 Ready
  • Single software suitable for upto 20 equipments
  • Automatic daily data back-up
  • Alarm logs. Alarm acknowledgement with e-signatures
  • Audit trails
  • MKT Calculations
  • Graphical viewing & data trending
  • Data export in pdf format
  • IQ, OQ, PQ
  • Calibration certificates
  • Operations & maintanance manuals
  • GA & Electrical drawings
  • Material test certificates
  • Training to end-users